Technical Specifications
| Feature | Specification |
|---|---|
| Power Output | 5 kW (6.3 kVA) |
| Output Voltage | 230 V (Single‑Phase) @ 50 Hz |
| Amperage per Phase | 22 A |
| Decibel Rating | 71 dB(A) |
| Fuel Consumption | 2.2 L/PH |
| Type | Petrol Powered |
| Tank Capacity | 22 L |
| Start Type | Pull Start or Electric Start |
| Voltage Regulator | Yes (AVR) |
| Oil Capacity | 1.1 L |
| Engine Displacement | 389 cc |
| Engine Model | JDP6500E |
| Total Running Time | 10 Hours |
Specifications Notification
Generators are rated to run at 80% of their maximum output at sea‑level in a neutral climate. Altitude and temperature can reduce engine efficiency and power output.
Expert Advice
Select a generator with at least 20% more capacity than your estimated need to avoid overloading and extend the unit’s lifespan.
Specifications Description
- Power Factor: 1
- 4‑Stroke, Air‑Cooled, Single‑Cylinder Engine
- Engine Speed: 3 600 RPM
An electrician should perform a load test to ensure compatibility with your required amperage per phase.
Limitations of Use:
- Do not exceed 50% of the generator’s rated load for the first-step load.
- Do not exceed 75% of the generator’s rated load for the running load.
These guidelines account for natural current fluctuations during petrol combustion.